Vantec EZ Swap M2500 Manual Page 2

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 1
v 1.01
www.vantecusa.com
Model: MRK-M2504T/MRK-M2508T/MRK-M2512T
L01
L02
L07
L08
B01
B02
B07
B08
L03
L04
L09
L10
B03
B04
B09
B10
L05
L06
L11
L12
B05
B06
B11
B12
D03
D04
D01
D02
D05
D06
D09
D10
D07
D08
D11
D12
P01 P02 P03
F01
SW1
L01
L02
L05
L06
B01
B02
B05
B06
L03
L04
L07
L08
B03
B04
B07
B08
D03
D04
D01
D02
D07
D08
D05
D06
P01 P02
F01
SW1
LED Indicators (L01-L04)
BLUE - Power ON
PURPLE - Disk performing reading/writing
RED - On all 4 LEDs (L0l-L04), constant ashing indicate FAN Failure
NO LED - No power to the drive bay, no drive in the tray
FANS (F01, F02)
Both Fans pull air from the front of the Storage Bays.
It uses two 40x40x20mm Fans.
If any one of the Fans fails, the Four LED (L01- L04) will start blinking RED
Over Heating
If the Four LED (L01 – L04) start to blink RED very rapidly, the temperature in
the Storage Bay have exceeded the safe temperature of 60 degree C.
Power Connector (P05)
Single Power connection for all 4 Bays
LED Function Switch (SW1)
Left
Blue for Power LED
No Disk Activity LED
Red for Fan Failure LED
Right
Blue for Power LED
Purple for Disk Activity LED
Red for Fan Failure LED
SATA/SAS Port Connectors (D01 - D04)
Data port (D01) - B01
Data port (D02) - B02
Data port (D03) - B03
Data port (D04) - B04
Note:
1) You can mix SATA and SAS drives in the same storage unit, but SATA drives
HAVE to be connected to SATA controller and SAS drive HAVE to be connected
to SAS controller
2) SAS drive only support Primary Channel
LED Indicators (L01-L08)
GREEN - Power ON
ORANGE - Disk performing reading/writing
NO LED - No power to the drive bay, no
drive in the tray
LED Temperature Status (T1)
Normal – No LED
Exceeded safe temp of 60 degrees C – Solid RED
LED Fan Status (F1)
Normal – No LED
Fan Failure – Solid RED
FANS (F01)
Fan pulls air from the front of the Storage Bays.
Fan size: 70x70mm
FAN Failure see F1 status
SATA/SAS Port Connectors (D01 - D08)
Data port (D01) - B01
Data port (D02) - B02
Data port (D03) - B03
Data port (D04) - B04
Data port (D05) - B05
Data port (D06) - B06
Data port (D07) - B07
Data port (D08) - B08
Note:
1) You can mix SATA and SAS drives in the same
storage unit, but SATA drives HAVE to be connected to
SATA controller and SAS drive HAVE to be connected
to SAS controller
2) SAS drive only support Primary Channel
L01
D03
D04
SW1
D01
D02
L02
L03
L04
B01
B02
P05
F02 F01
B03
B04
Power Connector (P01,P02)
Dual Power connection for all 8 Bays
Note:
-Both Power connectors must be
connected from the system power supply
-Power load balance by all attached drives
T +, TR - Temperature
F+, FR - Fan
Hdd+, l - HDD activity LED for B01
Hdd+, 2 - HDD activity LED for B02
Hdd+, 3 - HDD activity LED for B03
Hdd+, 4 - HDD activity LED for B04
Hdd+, 5 - HDD activity LED for B05
Hdd+, 6 - HDD activity LED for B06
Hdd+, 7 - HDD activity LED for B07
Hdd+, 8 - HDD activity LED for B08
Signal Extension Connectors
(HDD activity, Fan, Temperature)
HDD activity LED Switch(SW1)
ON – Show Disk Activity (Orange LED)
O – Show only Green Power LED
(If Drive(s) is in the tray)
Fan Speed Switch
Low – 2400 rpm
High – 3000 rpm
LED Indicators (L01-L12)
GREEN - Power ON
ORANGE - Disk performing reading/writing
NO LED - No power to the drive bay, no
drive in the tray
LED Temperature Status (T1)
Normal – No LED
Exceeded safe temp of 60 degree C – Solid RED
LED Fan Status (F1)
Normal – No LED
Fan Failure – Solid RED
FANS (F01)
Fan pulls air from the front of the Storage Bays.
Fan size: 80 x 80 x15mm
FAN Failure see F1 status
SATA/SAS Port Connectors (D01 - D12)
Data port (D01) - B01
Data port (D02) - B02
Data port (D03) - B03
Data port (D04) - B04
Data port (D05) - B05
Data port (D06) - B06
Data port (D07) - B07
Data port (D08) - B08
Data port (D09) - B09
Data port (D10) - B10
Data port (D11) - B11
Data port (D12) - B12
Note:
1) You can mix SATA and SAS drives in the same
storage unit, but SATA drives HAVE to be connected to
SATA controller and SAS drive HAVE to be connected
to SAS controller
2) SAS drive only support Primary Channel
Power Connector (P01,P02,P03
)
Three Power connection for all 12 Bays
Note:
-Three Power connectors must be
connected from the system power supply
-Power load balance by all attached drives
T+, TR - Temperature
F+, FR - Fan
Hdd+, l
- HDD activity LED for B01
Hdd+, 2
- HDD activity LED for B02
Hdd+, 3
- HDD activity LED for B03
Hdd+, 4
- HDD activity LED for B04
Hdd+, 5
- HDD activity LED for B05
Hdd+, 6
- HDD activity LED for B06
Hdd+, 7
- HDD activity LED for B07
Hdd+, 8
- HDD activity LED for B08
Hdd+, 9
- HDD activity LED for B09
Hdd+, 10 - HDD activity LED for B10
Hdd+, 11 - HDD activity LED for B11
Hdd+, 12 - HDD activity LED for B12
Signal Extension Connectors
(HDD activity, Fan, Temperature)
HDD activity LED Switch(SW1)
ON – Show Disk Activity (Orange LED)
O – Show only Green Power LED
(If Drive(s) is in the tray)
Fan Speed Switch
Low – 2400 rpm
High – 3000 rpm
Page view 1
1 2

Comments to this Manuals

No comments