Vantec UGT-IS100R User Manual Page 12

  • Download
  • Add to my manuals
  • Print
  • Page
    / 22
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 11
UGT-IS100R Page12
connection information, will be written to the replacement disk.
Rebuild Mirror Drive
When a failure to one member occurs, you will be notified by the
RAID BIOS during boot. The steps below will guide you in
rebuilding a failed mirror set.
1. Replace the failed drive(s) with one of equal or greater
capacity, start the computer.
2. During boot press Ctrl+J to enter the RAID BIOS.
3. Select Rebuild Mirror Drive press Enter.
4. Please use arrow keys and to select the array you want to
rebuild, press Enter.
5. Please use arrow keys and to select the destination disk,
press Enter.
6. When rebuilding is finished, select Save And Exit Setup,
press Enter. When asked Save to disk &Exit (Y/N)?, press
Y to exit the BIOS.
BIOS Configuration
The 4+1 SATA II 300 IDE/PATA PCI-E Combo Host Card w/ RAID
& Port Multiplier BIOS will appear every time your system starts
Page view 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 21 22

Comments to this Manuals

No comments